Basic Info.
After-sales Service
1 Year
Power Supply
380c, 50/60Hz, 3phase
Type
2-Zone or 3-Zone Optional
Controller
Programmable 7′′ Colorful Display
Service
OEM / ODM / Non-Standard Available
Inner Size
500*450*450mm(100liter)
Outer Size
1480*1950*1850mm
Cooling Type
Water Cooling / Air Cooling
Application
School, Hospital, Lab, Factory
Transport Package
Wooden Case for Export
Specification
Customization available
Product Description
Thermal Shock Test Chamber
Application: Hot and cold shock test chamber can be used to test the material structure or composite materials, in an instant by the very high temperature and very low temperature of the continuous environment can endure the degree, so as to test its thermal expansion and contraction caused by chemical changes or physical damage in the shortest possible time. Applicable objects include metals, automotive electronics, rubber, electrical and electronic, IC chips, LED lighting, aerospace and other important instruments and equipment for material testing and analysis, the test results can be used as an important basis for product improvement or reference.Standard Compliance:♦GB/T 11158-2008 High temperature test chamber technical conditions♦GB/T 10589-2008 Low temperature test chamber technical conditions♦GB/T 2423.1-2001 Environmental test for electrical and electronic products Part 2: Test method Test A: Low temperature♦GB/T 2423.2-2001 Environmental test for electrical and electronic products Part 2: Test method Test B: High temperature♦GB/T 2423.22-2002 Environmental test for electrical and electronic products Part 2: Test method Test N: Temperature change♦GJB150.3-86 Environmental test method for military equipment High temperature shock test♦GJB150.4-86 Environmental test method for military equipment Low-temperature shock test♦GJB150.5-86 Environmental test method for military equipment Temperature shock test♦GJB360.7-87 Test method for electrical and electronic components Temperature shock testProduct Parameters Model | ETS-100L |
Volume | 100L |
Test Method | Pneumatic dampers switching |
High temp. chamber | +60ºC~+200ºC |
Heating rate | +60ºC→+200ºC≤20min |
Low temp.chamber | -75ºC~0ºC |
Cooling rate | +20ºC→-70ºC≤85min |
Temperature deviation | ±2ºC |
Temperature uniformity | <=±2ºC |
Temp.shock range | A:-40ºC~125ºC B:-55ºC~125ºC C:-65ºC~125ºC (High temperature optional 150°C or higher) |
Recovery time | ≤5min |
Load capacity of shelf | 30KG |
Interior size (W*D*H mm) | 500*450*450 |
Exterior size (W*D*H mm) | 1480*1950*1850 |
Exterior material | SEEC salted steel plate + surface spraying treatment |
Interior material | Stainless steel plate(SUS 304) |
Insulation material | Rigid polyurethane Foam + glass fiber wool |
Heater | Nickel chromium alloy heating wire heater |
Fan | Stainless steel centrifugal fan |
Cooler | Fin cooler,Cold accumulator |
Driving device | Pneumatic cylinder drive |
Refrigeration device | Compressed air supply for pneumatic dampers (optional) |
Cooling method | Compound cooling system |
Compressor | France "Tecumseh",German "Bitzer" or "GEA" |
Refrigerant | R404a/R23/R508 |
Condenser | ShellandTubeHeatExchangers |
Screen | 7 Inch Programmable LCD Touch Screen |
Operation method | Program Method |
Setting method | Chinese / English Menu, Touch Input |
Program Capacity | 100 programs, each program 100 steps; each program can be set 999 times loop |
Display Resolution | Temperature:1ºC; Time:0.1min |
Input | Thermocouple |
Communication functions | RS-232 interface with local and remote communication capabilities |
Curve recording function | It can save the set value,sampling value of the device and the time of the sampling moment. |
Accessory Functions | Fault alarm and causes; Fault record; Over temperature protection; Upper and lower temperature protection; Power off protection; Alarm output; Timing function. |
Equipment power | AC 380±10% 50Hz ,3 phase 4 wires +Ground Wires |
Weight (about kg) | 15KW |
Circulating cooling water | 1580 |
Compressed air | Water pressure:(0.25-0.4)MPa |
Standard configuration | (0.5-0.8)MPa,0.1m3/min |
Safety device | 1 Test hole,4 Universal Wheels,2 Shelves |
Safety Configuration | Main power phase sequence and phase loss protection,Leakage protection,load short circuit protection;Compressor overload/ over voltage protection,compressor motor overheating,Over temperature protection,Fan motor overheating protection and so on. |
Address:
No. 31, Dongbei Road, Dongqiao Industrial Zone, Haishu District, Ningbo, Zhejiang, China
Business Type:
Manufacturer/Factory
Business Range:
Apparel & Accessories, Auto, Motorcycle Parts & Accessories, Electrical & Electronics, Industrial Equipment & Components, Instruments & Meters, Light Industry & Daily Use, Manufacturing & Processing Machinery, Security & Protection, Tools & Hardware
Company Introduction:
Our company offers variety of products which can meet your multifarious demands. We adhere to the management principles of "quality first, customer first and credit-based" since the establishment of the company and always do our best to satisfy potential needs of our customers. Our company is sincerely willing to cooperate with enterprises from all over the world in order to realize a win-win situation since the trend of economic globalization has developed with anirresistible force.